Concrete batching plant is a set of equipment designed for the production of concrete mix, which is characterized by large size and strong capacity. Today, the concrete batching plant (bsu) plays an invariable role in the construction industry. It is also known as concrete plant or concrete mixing unit.
Our client from Tajikistan has placed an order for our AJ 50 Stationary Concrete Plant with our company Aimix. As you can see from the picture below, our workers are loading its components such as twin-shaft compulsory concrete mixer, cement silo, etc. this stationary concrete plant can produce concrete mixes up to 50M3 per hour.
What capacity concrete mixing plant are you interested in? Aimix offers to buy concrete batching plant of different capacity, ranging from 25-240 m3/h.
Model | Stationary plant with skip | |||
AJ-25 | AJ-35 | AJ-50 | AJ-75 | |
Theoretical capacity (M3/h) | 25 | 35 | 50 | 75 |
Concrete mixer model (discharge volume / L) | JS500 | JS750 | JS1000 | JS1500 |
Mixing motor power (kW) | 18.5 | 30 | 2×18.5 | 2×30 |
Mixer cycle (C) | 67 | 72 | 72 | 72 |
Nominal loading volume (L) | 800 | 1200 | 1600 | 2400 |
Max. chip feed (mm) | Φ60 | Φ60 | Φ60 | Φ80 |
Standard crushed rock hopper volume (M3) | 3×3 | 3×5 | 3×8 | 3×12 |
Number of aggregate types (pcs.) | 2/3 | 2/3/4 | 3/4 | 3/4 |
Cement silo (tons) | 1×50 | 2×50 | 1×100 | 2×100 |
Max. Discharge height (M) | 3.8 | 4.1 | 4.1 | 4.1 |
Accuracy of aggregate weighing (kg) | (300~1000) ±2% | (300~1000) ±2% | (300~1000) ±2% | (300~1500) ±2% |
Powder weighing accuracy (kg) | (100~300) ±1% | (100~300) ±1% | (100~750) ±1% | (100~900) ±1% |
Water weighing accuracy (kg) | (60~150) ±1% | (60~150) ±1% | (100~300)±1% | (100~400) ±1% |
Additive weighing accuracy (kg) | (5~20) ±1% | (5~20) ±1% | (5~20) ±1% | (5~25) ±1% |
Total weight (tons) | ≈15 | ≈18 | ≈23 | ≈30 |
Total power(kW) | ≈65 | ≈75 | ≈100 | ≈140 |
Voltage | 380V/220V/415/440V, 50/60HZ, 3 phases |
Model | Belt Batching Plant | |||
AJ-60 | AJ-90 | AJ-120 | AJ-180 | |
Theoretical capacity (M3/h) | 60 | 90 | 120 | 180 |
Concrete mixer model (discharging volume / L) | JS1000 | JS1500 | MAO3000/2000(SICOMA) | MAO4500/3000(SICOMA) |
Mixing motor power (kW) | 2×18.5 | 2×30 | 2×37 | 2×55 |
Mixer cycle (C) | 60 | 60 | 65 | 65 |
Nominal loading volume (L) | 1600 | 2400 | 3000 | 4500 |
Max. chip feed (mm) | Φ60 | Φ80 | Φ80 | Φ80 |
Standard crushed rock hopper volume(M3) | 4×7 | 4×15 | 4×15 | 4×20 |
Number of aggregate types (pcs.) | 4/5 | 4/5 | 4/5/6 | 4/5/6 |
Cement silo (tons) | 2×100 | 3×100 | 4×200 | 4×200 |
Max. Discharge height (M) | 4.1 | 4.1 | 4.3 | 4.3 |
Accuracy of aggregate weighing (kg) | (300~1000)±2% | (300~1500)±2% | (300~2000) ±2% | (300~3000)±2% |
Powder weighing accuracy (kg) | (100~750) ±1% | (100~900) ±1% | (100~1200) ±1% | (100~1800) ±1% |
Water weighing accuracy (kg) | (100~300) ±1% | (100~400) ±1% | (100~600) ±1% | (100~800) ±1% |
Additive weighing accuracy (kg) | (5~20)±1% | (5~25) ±1% | (5~30) ±1% | (5~50) ±1% |
Total weight (tons) | ≈40 | ≈68 | ≈93 | ≈101 |
Total power(kW) | ≈110 | ≈160 | ≈220 | ≈290 |
Voltage | 380V/220V/415/440V, 50/60HZ, 3 phases |
Model | Popular mobile concrete plant | ||
AJY-25 | AJY-35 | AJY-50 | |
Theoretical performance | 25 | 35 | 50 |
Concrete mixer model (L discharge volume) | JS500 | JS750 | JS1000 |
Mixing motor power (kW) | 18.5 | 30 | 2×18.5 |
Mixer cycle (C) | 67 | 72 | 72 |
Nominal loading volume (L) | 800 | 1200 | 1600 |
Max. chip feed (mm) | Φ60 | Φ60 | Φ60 |
Standard crushed rock hopper volume (M3) | 2×3 | 2×5 | 3×5 |
Number of aggregate types (pcs.) | 2/3/4 | ||
Cement silo (tons) | 1×50 | 2×50 | 1×100 |
Max. Discharge height (M) | 3.8 | 3.8 | 4.1 |
Accuracy of aggregate weighing (kg) | (300~1500)±2% | (300~1500)±2% | (300~3000) ±2% |
Powder weighing accuracy (kg) | (100~300) ±1% | (100~300) ±1% | (250~900) ±1% |
Water weighing accuracy (kg) | (60~150) ±1% | (60~150) ±1% | (80~300) ±1% |
Additive weighing accuracy (kg) | – – | (8~20) ±1% | (8~20) ±1% |
Total weight (tons) | ≈15 | ≈22 | ≈26 |
Total power (kW) | ≈61 | ≈73 | ≈92 |
Voltage | 380V/220V/415/440V, 50/60HZ, 3 phases |
Model | Mobile bsu without fundament | ||
AJM-25 | AJM-35 | AJM-50 | |
Theoretical capacity (M3) | 25 | 35 | 50 |
Concrete mixer model (discharge volume / L) | JS500 | JS750 | JS1000 |
Mixing motor power (kW) | 18.5 | 30 | 2×18.5 |
Mixer cycle | 67 | 72 | 72 |
Nominal loading volume (L) | 800 | 1200 | 1600 |
Max. chip feed (mm) | Φ60 | Φ60 | Φ60 |
Standard crushed rock hopper volume (M3) | 2×3 | 2×5 | 3×8 |
Number of aggregate types | 2/3/4 | ||
Cement silo (tons) | 1×50 | 2×50 | 1×100 |
Max. Discharge height (M) | 3.8 | 4.1 | 4.1 |
Accuracy of aggregate weighing (kg) | (300~1500) ±2% | (300~1500) ±2% | (300~3000) ±2% |
Powder weighing accuracy (kg) | (100~300) ±1% | (100~300) ±1% | (250~900) ±1% |
Water weighing accuracy (kg) | (60~150) ±1% | (60~150) ±1% | (80~300) ±1% |
Additive weighing accuracy (kg) | – – | (8~20) ±1% | (8~20) ±1% |
Total weight (tons) | ≈15 | ≈18 | ≈23 |
Total power(kW) | ≈65 | ≈75 | ≈100 |
Voltage | 380V/220V/415/440V, 50/60HZ, 3 phases |
If you are interested in our concrete batching plants, you can place an order here and leave specific messages to receive our price and commercial offers.