AIMIX offers various concrete batching plants all over the world, among which the biggest concrete batching plant can produce concrete mixes up to 240M3/h, and mini concrete b atching plant can produce up to 25M3/h. What capacity concrete plant you need. Contact us and find out their preferential prices.
Do you want to learn more or buy?
Our AJ75 concrete batching plant was shipped to Russia in November 2018. This concrete plant is a popular model in AIMIX company. Its maximum capacity is 75 M3/hour.
Concrete batching plants: technical specifications:
Stationary plant with skip
Stationary belt mill
Mobile concrete plant
Plant without fundamentals
Model | Stationary plant with skip | |||
AJ-25 | AJ-35 | AJ-50 | AJ-75 | |
Theoretical capacity (M3/h) | 25 | 35 | 50 | 75 |
Concrete mixer model (discharge volume / L) | JS500 | JS750 | JS1000 | JS1500 |
Mixing motor power (kW) | 18.5 | 30 | 2×18.5 | 2×30 |
Mixer cycle (C) | 67 | 72 | 72 | 72 |
Nominal loading volume (L) | 800 | 1200 | 1600 | 2400 |
Max. chip feed (mm) | Φ60 | Φ60 | Φ60 | Φ80 |
Standard crushed rock hopper volume (M3) | 3×3 | 3×5 | 3×8 | 3×12 |
Number of aggregate types (pcs.) | 2/3 | 2/3/4 | 3/4 | 3/4 |
Cement silo (tons) | 1×50 | 2×50 | 1×100 | 2×100 |
Max. Discharge height (M) | 3.8 | 4.1 | 4.1 | 4.1 |
Accuracy of aggregate weighing (kg) | (300~1000) ±2% | (300~1000) ±2% | (300~1000) ±2% | (300~1500) ±2% |
Powder weighing accuracy (kg) | (100~300) ±1% | (100~300) ±1% | (100~750) ±1% | (100~900) ±1% |
Water weighing accuracy (kg) | (60~150) ±1% | (60~150) ±1% | (100~300)±1% | (100~400) ±1% |
Additive weighing accuracy (kg) | (5~20) ±1% | (5~20) ±1% | (5~20) ±1% | (5~25) ±1% |
Total weight (tons) | ≈15 | ≈18 | ≈23 | ≈30 |
Total power(kW) | ≈65 | ≈75 | ≈100 | ≈140 |
Voltage | 380V/220V/415/440V, 50/60HZ, 3 phases |
Do you want to learn more or buy?
Model | Belt Batching Plant | |||
AJ-60 | AJ-90 | AJ-120 | AJ-180 | |
Theoretical capacity (M3/h) | 60 | 90 | 120 | 180 |
Concrete mixer model (discharging volume / L) | JS1000 | JS1500 | MAO3000/2000(SICOMA) | MAO4500/3000(SICOMA) |
Mixing motor power (kW) | 2×18.5 | 2×30 | 2×37 | 2×55 |
Mixer cycle (C) | 60 | 60 | 65 | 65 |
Nominal loading volume (L) | 1600 | 2400 | 3000 | 4500 |
Max. chip feed (mm) | Φ60 | Φ80 | Φ80 | Φ80 |
Standard crushed rock hopper volume(M3) | 4×7 | 4×15 | 4×15 | 4×20 |
Number of aggregate types (pcs.) | 4/5 | 4/5 | 4/5/6 | 4/5/6 |
Cement silo (tons) | 2×100 | 3×100 | 4×200 | 4×200 |
Max. Discharge height (M) | 4.1 | 4.1 | 4.3 | 4.3 |
Accuracy of aggregate weighing (kg) | (300~1000)±2% | (300~1500)±2% | (300~2000) ±2% | (300~3000)±2% |
Powder weighing accuracy (kg) | (100~750) ±1% | (100~900) ±1% | (100~1200) ±1% | (100~1800) ±1% |
Water weighing accuracy (kg) | (100~300) ±1% | (100~400) ±1% | (100~600) ±1% | (100~800) ±1% |
Additive weighing accuracy (kg) | (5~20)±1% | (5~25) ±1% | (5~30) ±1% | (5~50) ±1% |
Total weight (tons) | ≈40 | ≈68 | ≈93 | ≈101 |
Total power(kW) | ≈110 | ≈160 | ≈220 | ≈290 |
Voltage | 380V/220V/415/440V, 50/60HZ, 3 phases |
Do you want to learn more or buy?
Model | Popular mobile concrete plant | ||
AJY-25 | AJY-35 | AJY-50 | |
Theoretical performance | 25 | 35 | 50 |
Concrete mixer model (L discharge volume) | JS500 | JS750 | JS1000 |
Mixing motor power (kW) | 18.5 | 30 | 2×18.5 |
Mixer cycle (C) | 67 | 72 | 72 |
Nominal loading volume (L) | 800 | 1200 | 1600 |
Max. chip feed (mm) | Φ60 | Φ60 | Φ60 |
Standard crushed rock hopper volume (M3) | 2×3 | 2×5 | 3×5 |
Number of aggregate types (pcs.) | 2/3/4 | ||
Cement silo (tons) | 1×50 | 2×50 | 1×100 |
Max. Discharge height (M) | 3.8 | 3.8 | 4.1 |
Accuracy of aggregate weighing (kg) | (300~1500)±2% | (300~1500)±2% | (300~3000) ±2% |
Powder weighing accuracy (kg) | (100~300) ±1% | (100~300) ±1% | (250~900) ±1% |
Water weighing accuracy (kg) | (60~150) ±1% | (60~150) ±1% | (80~300) ±1% |
Additive weighing accuracy (kg) | – – | (8~20) ±1% | (8~20) ±1% |
Total weight (tons) | ≈15 | ≈22 | ≈26 |
Total power (kW) | ≈61 | ≈73 | ≈92 |
Voltage | 380V/220V/415/440V, 50/60HZ, 3 phases |
Do you want to learn more or buy?
Model | Mobile bsu without fundament | ||
AJM-25 | AJM-35 | AJM-50 | |
Theoretical capacity (M3) | 25 | 35 | 50 |
Concrete mixer model (discharge volume / L) | JS500 | JS750 | JS1000 |
Mixing motor power (kW) | 18.5 | 30 | 2×18.5 |
Mixer cycle | 67 | 72 | 72 |
Nominal loading volume (L) | 800 | 1200 | 1600 |
Max. chip feed (mm) | Φ60 | Φ60 | Φ60 |
Standard crushed rock hopper volume (M3) | 2×3 | 2×5 | 3×8 |
Number of aggregate types | 2/3/4 | ||
Cement silo (tons) | 1×50 | 2×50 | 1×100 |
Max. Discharge height (M) | 3.8 | 4.1 | 4.1 |
Accuracy of aggregate weighing (kg) | (300~1500) ±2% | (300~1500) ±2% | (300~3000) ±2% |
Powder weighing accuracy (kg) | (100~300) ±1% | (100~300) ±1% | (250~900) ±1% |
Water weighing accuracy (kg) | (60~150) ±1% | (60~150) ±1% | (80~300) ±1% |
Additive weighing accuracy (kg) | – – | (8~20) ±1% | (8~20) ±1% |
Total weight (tons) | ≈15 | ≈18 | ≈23 |
Total power(kW) | ≈65 | ≈75 | ≈100 |
Voltage | 380V/220V/415/440V, 50/60HZ, 3 phases |